Voltage monitor Relay connection
Learn how to wire a voltage monitor relay in a DOL starter to protect 3-phase motors from phase loss, phase reversal, and voltage faults with easy connection steps.

voltage monitor relay wiring diagram
A voltage monitor relay may be applied in a DOL starter by connecting the three-phase supply to the sensing terminals on the relay, via its NO contact in series with the start button and contactor coil, and the relay output to the overload relay. That is, this provides automatic motor trip upon phase faults.
Formula & Table Summary:
Motor Start Condition: Voltage Healthy + Correct Phase Sequence + Overload NC = Contactor Energized
dol starter control circuit with relay
A voltage monitor relay (phase failure relay) within a DOL starter protects a motor against damage under conditions of phase loss, phase sequence improper, or abnormal voltage. This type of wiring has the relay sense all three phases (l1, l2 and l3) and as such will only enable the contactor to energize when correct conditions are met. Its normally open (NO) output contact has been connected in series with the starter control circuit so that only healthy voltage and phase conditions will cause the motor to start. Provided there is a fault, then the relay will break open the circuit immediately, shutting off the motor and creating no damage. Four -wire connection is a necessitated approach to safety and reliability of industrial 3-phase motors.
motor protection relay connection
| Condition | Relay Output | Motor Status |
|---|---|---|
| All phases OK | Closed | Running |
| Phase loss | Open | Stopped |
| Phase reversal | Open | Stopped |
Frequently Asked Questions - Voltage monitor Relay connection:
What is a voltage monitor relay?
A device that detects phase loss, phase reversal, and voltage faults in 3-phase systems.
Why use a voltage monitor relay in a DOL starter?
To protect motors from electrical faults and prevent damage.
Where is the relay installed?
It is connected in the control circuit of the DOL starter.
Which terminals connect to supply?
L1, L2, and L3 connect to the sensing inputs.
What does the NO contact do?
It closes when voltage and phases are correct, allowing the motor to start.
Does it work with single-phase motors?
No, it is designed for 3-phase systems.
What happens if a phase is lost?
The relay opens the circuit and stops the motor instantly.
Can it detect overvoltage?
Yes, most models can detect both under and over voltage.
Is it adjustable?
Yes, settings for voltage thresholds and delay can be adjusted.
Does it replace overload protection?
No, it works alongside the overload relay for full protection.
Related Posts

Day Night Light Sensor Switch Circuit
Learn how to wire a day night light sensor switch for automatic lighting control. Save energy and improve convenience with this simple guide and diagram.

Automatic water level controller wiring
Clear wiring diagram and guide for water pump automatic ON/OFF using a floatless relay, ensuring reliable pump control without mechanical floats.

Hospital wiring Diagram
Understand hospital wiring diagrams, including emergency systems, isolation panels, and backup supplies for safe and reliable healthcare facility operations.

3-Phase Distribution Board wiring diagram
Simple 3-phase distribution board wiring diagram for home use, showing safe connection of power supply, breakers, neutral, and earth for residential electrical systems.

Door Bell wiring Diagram
Learn the basic doorbell wiring diagram, connections, and components for a reliable home doorbell system installation with easy step-by-step guidance.

4 Switch 1 Light Control Wiring
A wiring diagram showing how to control one light using four different switches from different locations. Ideal for staircases or long corridors.